Bevel Back Weatherboard Installation

broken image


Bevel Back Weatherboard B.C.11 PROFILE PRINT DATE: 1:2 @ A4 01 1. Weatherboards must be coated with at least one coat all sides prior to fixing. Fixing points must be pre-drilled minimum 1mm smaller than the fastener. SCALE: SHEET NUMBER REVISION. Under E2/AS1, a drainage cavity is required where the risk score exceeds 12 for bevel-back and six for rusticated. Set out the window head heights to suit the weatherboard dimensions. A 175mm minimum clearance to finished ground or 100mm to permanent paving. Specifying narrower rather than wider boards. Specifying single nailing to each board. Metalcraft Bevel Back Weatherboard is a traditional cladding system blending in with modern and traditional design surroundings. Metalcraft Bevel Back Weatherboard is a low cost cladding for out buildings, garages and sheds and is available in Zincalume®, Galvsteel®, Colorsteel® Endura® and Colorsteel® Maxx®.

  1. Bevel Back Weatherboard Installation
  2. Bevel Back Weatherboard Installation Nz
  3. Bevel Back Weatherboard Installation Tool
  4. Bevel Back Weatherboard Installation Panels
  5. Bevel Back Weatherboard Installation Kit
select to download
select to download

3MasterSpec - Horizontal

4Installation Specification - Bevel Back Cavity Fixed

5HC-BEVELBACK-201

Window Sill Detail,

Aluminium Joinery Deutsch patch crysis: software, free download pc.

6HC-BEVELBACK-202

Window Jamb Detail,

Aluminium Joinery

7HC-BEVELBACK-210

Door Head Detail,

Aluminium Joinery

8HC-BEVELBACK-211

Door Sill Detail,

Bevel back weatherboard installation tool

Aluminium Joinery

9HC-BEVELBACK-212

Door Jamb Detail,

Bevel Back Weatherboard Installation

Aluminium Joinery

select to download
select to download
select to download

13HC-BEVELBACK-303

Enclosed Deck Balustrade to Wall Junction

select to download
select to download

16HC-BEVELBACK-410

General Detail Cavity Fix,

Stain Finish

17HC-BEVELBACK-411

Bevel Back Weatherboard Installation Nz

General Detail Cavity Fix,

Paint Finish

select to download

Bevel Back Weatherboard Installation Tool

select to download
select to download
Bevel

Aluminium Joinery

9HC-BEVELBACK-212

Door Jamb Detail,

Bevel Back Weatherboard Installation

Aluminium Joinery

select to download
select to download
select to download

13HC-BEVELBACK-303

Enclosed Deck Balustrade to Wall Junction

select to download
select to download

16HC-BEVELBACK-410

General Detail Cavity Fix,

Stain Finish

17HC-BEVELBACK-411

Bevel Back Weatherboard Installation Nz

General Detail Cavity Fix,

Paint Finish

select to download

Bevel Back Weatherboard Installation Tool

select to download
select to download
select to download
select to download

Bevel Back Weatherboard Installation Panels

select to download
select to download
select to download
select to download
select to download
select to download
select to download

Bevel Back Weatherboard Installation Kit

The Hermpac Bevelback and Rebated Bevelback Weatherboard Cavity System incorporating oil or stain-finished cedar and DuraLarch weatherboards and paint finished DuraLarch and AshinDura weatherboards has been appraised as an external wall cladding system for buildings within the following scope:

  • The scope limitations of NZBC Acceptable System E2/AS1 paragraph 1.1.
  • Constructed with timber framing complying with the NZBC.
  • With a risk score of 0-20 calculated in accordance with NZBC Acceptable Solution E2/AS1 Table 2.
  • Situated in NZS 3604 wind zones up to and including extra high.

The Hermpac Bevelback and Rebated Bevelback Weatherboard Cavity System incorporating oil or stain-finished weatherboards has also been appraised for weathertightness and structural wind loading when used as an external wall cladding system for buildings within the following scope:

  • The scope limitations of NZBC Acceptable Solution E2/AS1 paragraph 1.1 with regards to building height and floor plan area.
  • Constructed with timber framing subject to specific engineering design.
  • Situated in specific design wind pressures up to a maximum design differential ultimate limit state (ULS) of 2.5 kPa.

The Hermpac Bevelback and Rebated Bevelback Weatherboard Cavity System incorporating paint-finished cedar weatherboards has been appraised as an external wall cladding system for buildings within the following scope:

  • The scope limitations of NZBC Acceptable System E2/AS1 paragraph 1.1.
  • Constructed with timber framing complying with the NZBC.
  • With a risk score of 0-20 calculated in accordance with NZBC Acceptable Solution E2/AS1 Table 2.
  • Situated in NZS 3604 wind zones up to and including medium when studs are at maximum 600 mm centres and NZS 3604 wind zones up to and including very high when studs are at maximum 400 mm centres.

The Hermpac Bevelback and Rebated Bevelback Weatherboard Cavity System must only be installed horizontally on vertical, flat surfaces.

The Hermpac Bevelback and Rebated Bevelback Weatherboard Cavity System is appraised for use with aluminium window and door joinery that is installed with vertical jambs and horizontal heads and sills. (The Appraisal of the Hermpac Bevelback and Rebated Bevelback Weatherboard Cavity System relies on the joinery meeting the requirements of NZS 4211 for the relevant wind zone or wind pressure.)